What was found
PUNCTURED LT CUSP WEB Y=1007 BTW X=44 AT CABIN FLOOR STRUCTURE. CUSP WEB WAS FABRICATED AND REPLACED PER SRM 53-05 FIGURE 131A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PUNCTURED LT CUSP WEB Y=1007 BTW X=44 AT CABIN FLOOR STRUCTURE. CUSP WEB WAS FABRICATED AND REPLACED PER SRM 53-05 FIGURE 131A.