As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
VERTICAL STAB LEADING EDGE AT VSS ZFS 52.267 SPLICE HAS NUMEROUS LOOSE SCREWS & SCREWS PULLING INTO SKIN & ELONGATED HOLES. REPAIRED THE VERTICAL STAB LEADING EDGE SKIN IAW DWG SR95550001 AND JC 5530-01048-03. FABRICATED NEW SPLICE BAN IAW ER/A 549632-14 REV O AND INSTALLED IAW SR95550001.