What was found
CORROSION ON SETTLEMENT AREA AND COUNTERSINK OF FUEL ACCESS PLATE NBR 1367C. ACCESS PANEL WAS REPLACED PER IPC 57-30-00 AND MAGNETIC DRIPLESS FUEL MEASURING STICK WAS INSTALLED PER AMM 28-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON SETTLEMENT AREA AND COUNTERSINK OF FUEL ACCESS PLATE NBR 1367C. ACCESS PANEL WAS REPLACED PER IPC 57-30-00 AND MAGNETIC DRIPLESS FUEL MEASURING STICK WAS INSTALLED PER AMM 28-40-02.