What was found
DURING INSPECTION FOUND FWD CARGO PIT RT ZEE ANGLE STATION 500A TO 500I HAS UPPER SURFACE CORROSION. MAINTENANCE REMOVED AND REPLACED WITH NEW ZEE ANGLE IAW SRM 51-40- 02 PG 2 & 51-40-05 PG 4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND FWD CARGO PIT RT ZEE ANGLE STATION 500A TO 500I HAS UPPER SURFACE CORROSION. MAINTENANCE REMOVED AND REPLACED WITH NEW ZEE ANGLE IAW SRM 51-40- 02 PG 2 & 51-40-05 PG 4.