What was found
DURING INSPECTION FOUND FORWARD CARGO LT FLOOR Z ANGLE CORRODED BS 500 B+12" TO BS 500I LBL 24. MAINTENANCE REMOVED AND REPLACED FORWARD CARGO LEFT HAND Z ANGLE STATION 410 TO STATION 500I IAW SRM 53-00-53 REPAIR 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND FORWARD CARGO LT FLOOR Z ANGLE CORRODED BS 500 B+12" TO BS 500I LBL 24. MAINTENANCE REMOVED AND REPLACED FORWARD CARGO LEFT HAND Z ANGLE STATION 410 TO STATION 500I IAW SRM 53-00-53 REPAIR 5.