What was found
CORROSION ON I/B PLATE LOCATED AT RT AILERON LOWER SURFACE L/E AREA, MEASURES L 10" , W 1" , D 0.001 APPROX. REPLACED I/B PLATE LOCATED AT RT AILERON LOWER SURFACE L/E AREA AND FASTENERS AS PER SRM 51-72-11 AND DWG D57640040.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON I/B PLATE LOCATED AT RT AILERON LOWER SURFACE L/E AREA, MEASURES L 10" , W 1" , D 0.001 APPROX. REPLACED I/B PLATE LOCATED AT RT AILERON LOWER SURFACE L/E AREA AND FASTENERS AS PER SRM 51-72-11 AND DWG D57640040.