What was found
DURING INSPECTION FOUND AFT CARGO LT Z ANGLE CORRODED AROUND FASTENER HOLES STATION 727 TO 727I+10. MAINTENANCE INSTALLED NEW Z ANGLE FROM STATION 727-847 IAW SRM 51-40-02, 53-00-53. REPAIR 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND AFT CARGO LT Z ANGLE CORRODED AROUND FASTENER HOLES STATION 727 TO 727I+10. MAINTENANCE INSTALLED NEW Z ANGLE FROM STATION 727-847 IAW SRM 51-40-02, 53-00-53. REPAIR 5.