What was found
CRACK ON PRODUCTION DOUBLER IN ELEVATOR ACCUMULATOR ACCESS DOOR FRAME AT BS 1474. DOUBLER WAS REPLACED IAW SRM 51-30-5, 51-30-2 AND DWG 5917686-7 REV AA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK ON PRODUCTION DOUBLER IN ELEVATOR ACCUMULATOR ACCESS DOOR FRAME AT BS 1474. DOUBLER WAS REPLACED IAW SRM 51-30-5, 51-30-2 AND DWG 5917686-7 REV AA.