As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION FOUND AFT CARGO PIT FLOOR SUPPORT HAS LIGHT CORROSION ON UPPER SURFACE AT FLOOR PANEL SPLICE STRAP LOCATION BS 727I+6" AT RBL 3. MAINTENANCE REMOVED CORROSION ON FLOOR SUPPORT STATION 727I+6" AT RBL3 AND REPAIRED IAW ER/A 462969-14MA.