What was found
CORROSION ON COUNTERSINK AND SETTLEMENT AREA OF FUEL ACCESS PLATE 620MB. CORROSION ON COUNTERSINK OF FUEL ACCESS PLATE 620MB WAS REMOVED IAW SRM 51-10-04 AND WAS MEASURED MAX DIAMETER ALLOWED IS 0.532" AND MAX DIAMETER MEASURE IS 0.58" IN 3 HOLES ADJACENT THEREFORE IS OUT OF LIMITS IAW SRM 57-10-01 CONDITION II (1)(A). REPLACE ACCESS PLATE AND VERIFIED WITH IPC 57-23-01.