What was found
DURING INSPECTION, FOUND AFT CARGO BAY SIDEWALL SUPPORT CORRODED IN NUMEROUS LOCATIONS FROM BS 727E + 10 - 767. MAINTENANCE FABRICATED NEW SIDEWALL SUPPORT, TREATED, PRIMED, APPLIED CORROSION INHIBITING COMPOUND AND INSTALLED IAW SRM 53-00-53, 51-40-05, 51-40-06, 51-20-01, 51-40-02, AND 51-10-02.