What was found
CRACK ON INNER PAN STA Y=370 IN BEAM 3 (FWD EDGE) AT FWD CARGO COMPARTMENT DOOR. HFEC INSPECTION WAS ACCOMPLISHED IN BEAM 3 AT FWD CARGO COMPARTMENT DOOR ,ONE CRACK OF 2.125" WAS FOUND PER NDTSPM 06-10-01.001. STOP DRILL WAS PERFORMED ON INNER PAN STA Y=370 IN BEAM 3 (C1) PER SRM 52-30-02 FIG 201 SHEET 2. HFEC WAS ACCOMPLISHED ON INNER PAN STA Y=370 IN BEAM 3 (FWD EDGE) AT FWD CARGO COMPARTMENT DOOR, NO CRACKS WERE FOUND AFTER STOP DRILL, PER NDT SPM 06-10-01.001. CRACK ON INNER PAN WAS REPAIRED PER SRM 52-30-02 FIG 201.