What was found
UPPER SURFACE OF FLOOR SUPPORT AT BS 186 HAS LIGHT CORROSION AROUND THE FLOOR PANEL FASTENER HOLES AND FOUND OUT OF LIMITS IAW SRM 53-00-00. REPLACED THE FLOOR SUPPORT IAW SRM 51-41-02, 51-41-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPPER SURFACE OF FLOOR SUPPORT AT BS 186 HAS LIGHT CORROSION AROUND THE FLOOR PANEL FASTENER HOLES AND FOUND OUT OF LIMITS IAW SRM 53-00-00. REPLACED THE FLOOR SUPPORT IAW SRM 51-41-02, 51-41-05.