What was found
CORROSION ON SUB FLOOR AT BS 160-200 AT RBL 50. BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-55. PG 101 STEP 4. REPAIRED IAW ER/A 551819-14MA REV 0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON SUB FLOOR AT BS 160-200 AT RBL 50. BLENDED THE CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-55. PG 101 STEP 4. REPAIRED IAW ER/A 551819-14MA REV 0.