As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION FOUND R-1 DOOR CREASE CHORD CORRODED IN SEVERAL AREAS STATION 291 TO 328. MAINTENANCE REMOVED R1 INNER CHORD, INSTALLED EWIS PROTECTION, VERIFIED NEW PART IAW DWG 141A8315 REV - & A TAG A15680. LOCATED & DRILLED R1 INNER CHORD, INSTALLED R1 INNER CHORD IAW DWG# 141A8310 REV-, SRM 51-40-02.