What was found
DURING INSPECTION FOUND AFT CARGO FLOOR SUPPORT CHANNEL REPAIR CORRODED AT NUT PLATE LOWER SURFACE BS 767+5" RBL 3. MAINTENANCE FABRICATED NEW REPAIR, LOCATED, DRILLED PRIMED AND INSTALLED IAW ER/A 492969-14MA, SRM 53-00-53, 51-10-02 AND AMM 51-21-72-370-804, 51-21-41-370-802 AND APPLIED CIC IAW SRM 51-21-91-620-802.