What was found
CORROSION ON FLOOR SUPPORT OF STA Y= 195 BTW STA X=16 TO X=42. FLOOR SUPPORT STA Y= 195 BTW STA X=16 TO X=42 WAS REPLACE PER SRM 51-10-4,51-30-2,51-30-5 AND 51-10-3 PAR 14 AND 21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT OF STA Y= 195 BTW STA X=16 TO X=42. FLOOR SUPPORT STA Y= 195 BTW STA X=16 TO X=42 WAS REPLACE PER SRM 51-10-4,51-30-2,51-30-5 AND 51-10-3 PAR 14 AND 21.