What was found
DURING INSPECTION FOUND E&E COMPT DOOR CUT OUT, RT VERT WEB IS SCRATCHED ABOVE DOOR LATCH RECEPTACLE. MAINTENANCE REMOVED AND REPLACE INSIDE THE E&E COMPARTMENT DOOR CUT OUT RT VERTICAL WEB IAW SRM 51-40-02 AND DWG 141A8512 REV J.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND E&E COMPT DOOR CUT OUT, RT VERT WEB IS SCRATCHED ABOVE DOOR LATCH RECEPTACLE. MAINTENANCE REMOVED AND REPLACE INSIDE THE E&E COMPARTMENT DOOR CUT OUT RT VERTICAL WEB IAW SRM 51-40-02 AND DWG 141A8512 REV J.