What was found
DURING INSPECTION FOUND PASSENGER CABIN FROM STATION 967-986.5 AFT ENTRY DOOR CREASE BEAM HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE REMOVE AND REPLACED AFT ENTRY DOOR CREASE BEAM IAW SRM 53-70-51, 51-40-02 DWG 147A8501 REB B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND PASSENGER CABIN FROM STATION 967-986.5 AFT ENTRY DOOR CREASE BEAM HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE REMOVE AND REPLACED AFT ENTRY DOOR CREASE BEAM IAW SRM 53-70-51, 51-40-02 DWG 147A8501 REB B.