What was found
MID LAVATORY WHITE EMERGENCY LIGHT INOPERATIVE. VERIFIED BATTERY PACK OPS CHECKED OK. PERFORMED CONTINUITY CHECK BETWEEN M732 D70 PIN 14 TO PIN 27 ON CONNECTOR D5294 AND GD3038-DC TO PIN 28 ON CONNECTOR D2594 CHK OK. AFTER EXTENSIVE TROUBLESHOOTING, FOUND SPLICE L2-J2 BROKEN. REPAIRED SAME. ALL WORK ACCOMPLISHED IAW CMM 25-40-39 AND WDM 33-51-21. EMERGENCY LIGHT ON MID LAVATORY. OPS CHECKED OK.