What was found
CRACKED BEAM NR 1 AT AFT END, ALSO BEAM CLIP SAME AREA, AT FWD SERVICE DOOR. BEAM NR 1 AND CLIP AFT EDGE WERE REPLACED PER SRM 51-41-02, 51-41-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED BEAM NR 1 AT AFT END, ALSO BEAM CLIP SAME AREA, AT FWD SERVICE DOOR. BEAM NR 1 AND CLIP AFT EDGE WERE REPLACED PER SRM 51-41-02, 51-41-05.