What was found
CRACKED FWD CARGO DOOR PAN BETWEEN STOP FITTINGS 1 & 2. HFEC INSPECTION WAS ACCOMPLISHED AND THE CRACKS WERE CONFIRMED IN FWD SECTION OF 1.625", AND AFT SECTION OF 1.5" IAW NDTSPM 06-10-01.001. STOP DRILLED IAW SRM 52-30-02 FIGURE 201 SHEET 3 OF 3, HFEC INSPECTION WAS ACCOMPLISHED , AND NO CRACKS WERE FOUND IAW NDTSPM 06-10-01.001. REPAIRED IAW SRM 52-30-02 REPAIR 4 FIGURE 201.