What was found
EXCESSIVE CORROSION ON RT CUSP WEB ON STA Y=550 IN REF CARD 00393. CRACK WAS FOUND WITH NEXT DIMENSION L=.320" DAMAGED AREA WAS TRIMMED OUT PER SRM 53-00-55. HFEC INSPECTION WAS ACCOMPLISHED ON RT CUSP WEB ON STA Y=550 AFTER TRIM OUT AND NO CRACKS WERE FOUND PER NDT SPM 06-10-01 .001 EQUIPMENT: MENTOR C/N: 1205 EXP DATE 24AUG17, AREA WAS REPAIRED PER SRM 53-00-55 FIG 215, 51-10-4 PAR 15,21, 51-41-02 AND 51-10-04 PAR 37.