What was found
SEVERAL CORROSION POINTS ON WEB UNDER FLOOR PANEL 211ANF. A DOUBLER WAS FABRICATED IAW DWG 9936533 REV CM. A NEW SUPPORT WAS INSTALLED IAW SRM 51-41-02, 51-41-05, AND 51-41-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEVERAL CORROSION POINTS ON WEB UNDER FLOOR PANEL 211ANF. A DOUBLER WAS FABRICATED IAW DWG 9936533 REV CM. A NEW SUPPORT WAS INSTALLED IAW SRM 51-41-02, 51-41-05, AND 51-41-01.