Service difficulty report · Control Unit · Doug MD9030

Difficulty date
January 12, 2017
Submitted
January 24, 2017
Operation
Air carrier
Aircraft
N909DA
Make and model
Doug MD9030
Aircraft serial
53389
Aircraft time
56,923 hours, 30,766 cycles
Part
Control Unit
Condition
Malfunctioned
Location
Electrical Sys
Stage of operation
LD
How discovered
O
Nature of condition
H
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LOST ALL ELECTRICAL POWER ON TOUCHDOWN. EMERGENCY POWER DID NOT PICK UP BUSS. EMERGENCY POWER AUTO FAULT WARNING ANNUNCIATED ON EOAP. EMERGENCY LIGHTS WORKED. WHEN EXTERNAL POWER APPLIED ALL BUSSES CAME ONLINE. NOTED LEFT AND RIGHT COOLING FAN CIRCUIT BREAKERS POPPED. CORRECTIVE ACTION: MAINTENANCE FOUND LEFT HEAT EXCHANGER FAN CIRCUIT BREAKER POPPED. RESET 2 EACH PHASE BREAKERS. RAN ENGINES AND 3 PHASES BREAKERS POPPED. FWD LEFT HEAT EXCHANGER FAN TO MCO/PLAC PER MEL 21-55-01. REMOVED AND REPLACED EPCU. REMOVED AND REPLACED HEAT EXCHANGER COOLING FAN IAW MM. OPERATION CHECKS OK.