What was found
FLOORBEAM BS 256 LBL 22 TO RBL 22 CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00 FIG 103. . REMOVED IAW SRM 51-41-02. FABRICATED, ALODINED, PRIMED, AND TOP COATED IAW AMM 51-10-00 370-803. INSTALLED IAW SRM 51-41-05.