What was found
CRACKED 2 INTERCOSTALS AND PLATE AT KEEL BEAM STA 937 BETWEEN X=7 AND X=-7. INTERCOSTALS (2 E/A) AND PLATE WAS REMOVED, FABRICATED AND INSTALLED PER DWG 9936368 REV AW SRM 51-30-5 AND 53-14-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED 2 INTERCOSTALS AND PLATE AT KEEL BEAM STA 937 BETWEEN X=7 AND X=-7. INTERCOSTALS (2 E/A) AND PLATE WAS REMOVED, FABRICATED AND INSTALLED PER DWG 9936368 REV AW SRM 51-30-5 AND 53-14-3.