What was found
TWO SPLICES FOR SEAL RETAINER HAVE LIGHT CORROSION AT BOTTOM AREA OF DOOR PAN. FOUND TO BE OUT OF LIMITS. FABRICATED NEW SPLICES IAW DWG 5910158 AND INSTALLED IAW SRM 51-41-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TWO SPLICES FOR SEAL RETAINER HAVE LIGHT CORROSION AT BOTTOM AREA OF DOOR PAN. FOUND TO BE OUT OF LIMITS. FABRICATED NEW SPLICES IAW DWG 5910158 AND INSTALLED IAW SRM 51-41-02.