What was found
DENT LOCATED AT LT FUSELAGE STA 239 BTWN L20L & L23L. MEASURED DENT AT LT FUSELAGE STA 239 BETWEEN L20L & L23L FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01. FABRICATED, REPAIR DOUBLER AND INSTALLED IAW SRM 53-00-01 REPAIR 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DENT LOCATED AT LT FUSELAGE STA 239 BTWN L20L & L23L. MEASURED DENT AT LT FUSELAGE STA 239 BETWEEN L20L & L23L FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01. FABRICATED, REPAIR DOUBLER AND INSTALLED IAW SRM 53-00-01 REPAIR 3.