What was found
DURING INSPECTION FOUND A CRACK ON THE FLOOR SUPPORT BS 1016 AND RBL 35. REPLACED THE FLOOR SUPPORT IAW SRM 13737-700 51-10-02 ITEM 9, 51-40-02 AND DWG 148A0922.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND A CRACK ON THE FLOOR SUPPORT BS 1016 AND RBL 35. REPLACED THE FLOOR SUPPORT IAW SRM 13737-700 51-10-02 ITEM 9, 51-40-02 AND DWG 148A0922.