What was found
DENT IN FUSELAGE RT SIDE BELOW R2 DOOR- 2.5 IN IN DIA. 0.10 IN DEEP. 6.5IN BELOW LAP JOINT STGR31, 1.5 IN AFT OF STA 20878/FR31. CLEANED AND INSPECTED DENT, NO CRACKS FOUND. DURING LAYOVER IN MSP, IT WAS FOUND DURING A REINSPECT, THE DENT WAS MORE EXTENSIVE THAN ORIGINALLY REPORTED. THE ORIGINAL REPORT DATE WAS 10SEP16. THE DENT AND GOUGE ARE WITHIN THE ALLOWABLE DAMAGE LIMITS AS SET PER SRM 53-21-11 WITH THE EXCEPTION OF THE 0.59" 'B' (CENTER OF FASTENER TO EDGE OF DENT) REQUIREMENT AND SINCE IT IS A COMBINATION OF A DENT AND GOUGE. PERMANENT REPAIR WILL REMOVE DAMAGED SKIN AND INSTALL REPAIR DOUBLER PER SRM 53-21-11-FIG 204 AND ER/A 555389-14.