What was found
L2 DOOR CUTOUT STA 680 TO STA 740 LOWER THRESHOLD PLATE/SEAL FRAME(BEAM)CORRODED. REMOVED CORROSION IAW SRM 51-10-02, VERIFIED WITH A 10X MAG GLASS, NO DEFECTS FOUND. ORIGINAL .056 REMAIN .049 LOSS .007 FOUND TO BE OUT OF LIMITS IAW SRM 53-30-15 ALLOWABLE DAMAGE 1. REMOVED AND REPLACED LOWER THRESHOLD PLATE IAW DRAWING 143N5400 SHT 1 REV B, AND 143N8322 SHT 3 REV-.