What was found
FWD CABIN WET AREA R1 ENTRANCE INTERCOSTAL BETWEEN STA-343 ANDSTA-363 RBL-46" HAS CRACKS AT 2 EACH FASTENER HOLE NUT PLATES. REMOVED & REPLACED CRACKED INTERCOSTAL STA 343-363 RBL 46 IAW SRM 51-40-02 & DWG 141N5160 REV E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CABIN WET AREA R1 ENTRANCE INTERCOSTAL BETWEEN STA-343 ANDSTA-363 RBL-46" HAS CRACKS AT 2 EACH FASTENER HOLE NUT PLATES. REMOVED & REPLACED CRACKED INTERCOSTAL STA 343-363 RBL 46 IAW SRM 51-40-02 & DWG 141N5160 REV E.