What was found
CORROSION ON FLOOR SUPPORT BS 160 - 200 BETWEEN LBL 44 AND 54. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00-1A, AND 51-30-07-0G FIG 9.J. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-40-08 0G AND SRM 51-30-07 0G FIG. 9(J) AND 19.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT BS 160 - 200 BETWEEN LBL 44 AND 54. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00-1A, AND 51-30-07-0G FIG 9.J. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-40-08 0G AND SRM 51-30-07 0G FIG. 9(J) AND 19.