What was found
DURING INSPECTION, FOUND EMERGENCY LIGHT CENTER FORWARD GALLEY INOPERATIVE. MAINTENANCE REMOVED LIGHT ASSY L108 AND INSTALLED A NEW LIGHT ASSY IAW AMM 33-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND EMERGENCY LIGHT CENTER FORWARD GALLEY INOPERATIVE. MAINTENANCE REMOVED LIGHT ASSY L108 AND INSTALLED A NEW LIGHT ASSY IAW AMM 33-51.