What was found
DURING INSPECTION FOUND AFT CARGO PIT FLOORBOARD Z ANGLE HAS CORROSION AT BS 737 TO BS 794 AT S25R. MAINTENANCE REMOVED AND REPLACED NED Z ANGLE ON AFT CARGO RT FRM STA 727G-767 IAW SRM 53-00-53 REPAIR 5 .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND AFT CARGO PIT FLOORBOARD Z ANGLE HAS CORROSION AT BS 737 TO BS 794 AT S25R. MAINTENANCE REMOVED AND REPLACED NED Z ANGLE ON AFT CARGO RT FRM STA 727G-767 IAW SRM 53-00-53 REPAIR 5 .