What was found
AFT CARGO COMPARTMENT LT TIE DOWN AT STA 1540 IS BENT UP ON ONE SIDE. AND CORROSION IS PRESENT. REMOVED AND INSTALLED NEW TIE DOWN LT SIDE AT STA 1540 IAW SRM 51-40-02. FOUND TO BE CORRODED 100% OUT OF LIMITS IAW SRM 53-00-53. VERIFIED NEW PART TIE DOWN FROM DRAWING PL* 146N1018 LOCATED & DRILLED NEW PART AT STA 1540 IAW SRM 51-40-05 AND INSTALLED TIE DOWN AT STA 1540 LT SIDE IAW SRM 51-40-02 AND DRAWING 146N1018 REV A.