As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION FOUND AFT CARGO COMPARTMENT FLOOR STRUCTURE STATION 767 TO 827 LEFT SIDE ZEE ANGLE CORRODED ON UPPER SURFACE AROUND FASTENER HOLES TASK 53-140. MAINTENANCE REMOVED AND REPLACED ZEE ANGLE IN AFT PIT STATION 767-827 LT IAW SRM 53-00-53 REPAIR 5.