What was found
PASSENGER CABIN AFT WET AREA FLOOR STRUCTURE STA 1600+3 RBL 45 LAV MOUNT FITTING CORRODED. REMOVED OLD MOUNT IAW SRM 51-40-02 STEP 4E. DRILLED IAW SRM 51-40-05. INSTALLED IAW SRM 51-40-02 STEP D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PASSENGER CABIN AFT WET AREA FLOOR STRUCTURE STA 1600+3 RBL 45 LAV MOUNT FITTING CORRODED. REMOVED OLD MOUNT IAW SRM 51-40-02 STEP 4E. DRILLED IAW SRM 51-40-05. INSTALLED IAW SRM 51-40-02 STEP D.