What was found
PASSENGER CABIN AFT WET AREA FLOOR STRUCTURE STA 1620+18" RBL45 LAV MOUNT FITTING CORRODED. REMOVED OLD MOUNT IAW SRM 51-40-02 STEP D6. DRILLED AND COUNTERSINK IAW SRM 51-40-05 AND SRM 51-40-08. INSTALLED WET IAW SRM 51-40-02 STEP D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PASSENGER CABIN AFT WET AREA FLOOR STRUCTURE STA 1620+18" RBL45 LAV MOUNT FITTING CORRODED. REMOVED OLD MOUNT IAW SRM 51-40-02 STEP D6. DRILLED AND COUNTERSINK IAW SRM 51-40-05 AND SRM 51-40-08. INSTALLED WET IAW SRM 51-40-02 STEP D.