What was found
FWD PASSENGER CABIN AT STA 338 TO STA 365, 26" I/B OF LBL 24, FLOORBEAM HAS SEVERAL AREAS OF CORROSION. REMOVED CORROSION FROM STA 338 TO 356 AT RBL 2 IAW 51-10-02 STEP 15. ORIGINAL .063" REMAINING .020" REMOVED .043" FOUND TO BE OUT OF LIMITS IAW SRM 53-0051 DETAIL III. REMOVED, LOCATED, DRILLED AND INSTALLED NEW FLOORBEAM IAW SRM 51-40-02, 51-40-05, AND DRAWING 141N5190 SHEET 1 REV C.