What was found
UPPER CABIN FLOOR SUPPORT IS CORRODED AT BS 200, LBL 56 UNDER FWD LEFT LAVATORY OTBD FLOOR PANEL. BLENDED THE FLOOR SUPPORT IAW SRM 53-00-00-1A. FABRICATED A NEW FLOOR SUPPORT IAW DWG 9910078, AND INSTALLED IAW SRM 51-41-05-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPPER CABIN FLOOR SUPPORT IS CORRODED AT BS 200, LBL 56 UNDER FWD LEFT LAVATORY OTBD FLOOR PANEL. BLENDED THE FLOOR SUPPORT IAW SRM 53-00-00-1A. FABRICATED A NEW FLOOR SUPPORT IAW DWG 9910078, AND INSTALLED IAW SRM 51-41-05-0G.