What was found
DURING INSPECTION, FOUND AFT PIT VERTICAL INTERCOSTAL CORRODED BETWEEN STATION 847-857 RBL 21. MAINTENANCE INSTALLED NEW INTERCOSTAL PER B737-800 SRM 51-40-02 STEP 4E AND 7D(C) AND BAC DWG# 146A8120 REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.