DURING INSPECTION, FOUND THE FWD CARGO BAY RT ZEE ANGLE CORRODED AROUND FASTENER HOLES BS 490 - 500A. MAINTENANCE REMOVED AND REPLACED THE ANGLE IAW DWG 143A0080, REV A.