As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSPECTION FOUND AFT CARGO COMPARTMENT FLOOR STRUCTURE BS 867 LBL 3. TIE DOWN FITTING BEAM CORRODED ON UPPER SURFACE AROUND FASTENER HOLES. MAINTENANCE REPLACED NEW TIE DOWN FITTING CHANNEL ON AFT CARGO COMP FROM STATION 847-887 LBL 3 IAW SRM 53-00-53-0G & 51-40-02-0G, PAGE 2, PARA 4 & DWG 146A7501 REV A.