What was found
PASSENGER CABIN AFT WET AREA FLOOR STA 1681 TO 1720 BL0 TO RBL52 SHEAR WEB CORRODED ON UPPER AROUND FASTENER HOLES SURFACE. BLENDED CORRODED AREAS ON CABIN AFT WET AREA UPPER SHEAR WEB STA 1681-1720 BLO-RBL52. VERIFIED DEEPEST BLENDED AREA TO BE ORG "T " .070 REMAINING "T".054 LOSS OF .017 FOUND TO BE OUT OF LIMITS. REPAIRED BLEND AREA AT STA 1687 BLO-RBL10. TREATED, PRIMED, TOPCOATED, AND CIC BLENDED AREAS IAW SRM 53-60-51 AND SRM 53-60-51 REPAIR 2 ALTERNATE I.