What was found
CORROSION ON FLOOR SUPPORT BTW STA Y=160-200 AND X=-44. FLOOR SUPPORT BTW STA Y=160-200 AND X= -44 WAS REPLACED PER SRM 53-14-1 FIG 11 AND 51-10-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT BTW STA Y=160-200 AND X=-44. FLOOR SUPPORT BTW STA Y=160-200 AND X= -44 WAS REPLACED PER SRM 53-14-1 FIG 11 AND 51-10-4.