What was found
BURNING SMELL IN COCKPIT FROM CB PANEL ABOVE FO. FOUND WIRE FOR CENTER FCC SERVO ON POWER SIDE OF BREAKER CHAFING ON FRAME. PERFORMED REPAIR SPLICE IAW SWPM CH 20-11. OPS CHECKS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BURNING SMELL IN COCKPIT FROM CB PANEL ABOVE FO. FOUND WIRE FOR CENTER FCC SERVO ON POWER SIDE OF BREAKER CHAFING ON FRAME. PERFORMED REPAIR SPLICE IAW SWPM CH 20-11. OPS CHECKS NORMAL.