What was found
AFTER TURNING ON BOTH PACKS, HAD A BURNING PACK ODOR. PERFORMED ALT DUCT BURNOUT AND REPLACED COALESSER BAGS IAW 4950-2215 AND 2170-4139 CHECKED GOOD. FOUND HYD LEAK ON LT THRUST REVERSER CONTROL VALVE B-NUT, SECURED AND CHECKED GOOD. PERFORMED 2900-2002 AND 2900-2003. CLEANED APU INLET IAW 4900-1184. CHECKED GOOD, OK FOR SERVICE .