What was found
FUEL TANK ACCESS PANEL CORRODED OUT OF LIMITS. THE ACCESS PANEL WAS REPLACED IAW SRM 51-22-2A CONDITION II (A) (1).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUEL TANK ACCESS PANEL CORRODED OUT OF LIMITS. THE ACCESS PANEL WAS REPLACED IAW SRM 51-22-2A CONDITION II (A) (1).